Home
About
Terms of Service
How to order
Productlines
Encoders
Rotary Encoders
Angle Encoders
Linear Encoders
Glass Discs
Electronic/Controls
PLC/DCS Modules
Electronic Drives & Controls
Hydraulic and Pneumatic
Hydraulic Valves
Hydraulic Pumps
Hydraulic Motors
Other Products
View All
Brands
HEIDENHAIN
PRECIZIKA
RSF
SIEMENS
B&R
REXROTH
MOOG
PARKER
HYDAC
HAWE
EATON/VICKERS
ATOS
Solution
Hydraulic System
CNC retrofit projects
Motion Control Solutions
Automation Lines
Marine Port Machinery
Industrial Machines
Mobile Hydraulic Industry
Blog
Contact
Productlines
B&R
X20AT4222 X20 Input Module - B&R Supplier in China
Products List
Encoders
Rotary Encoders
Angle Encoders
Linear Encoders
Glass Discs
Electronic/Controls
PLC/DCS Modules
Electronic Drives & Controls
Hydraulic and Pneumatic
Hydraulic Valves
Hydraulic Pumps
Hydraulic Motors
Brands
HEIDENHAIN
PRECIZIKA
RSF
SIEMENS
B&R
REXROTH
MOOG
PARKER
HYDAC
HAWE
EATON/VICKERS
ATOS
Other Products
Featured Products
Rexroth Piston Pump A10VSO 32 - with Fast Delivery
Rexroth Axial Piston Variable pump A4VSO
Flow Control Valves 2FRM - Bosch Rexroth Valve for Sale
Rexroth Solenoid Valve 4WE STOCKS FOR SALE
MOOG Servo valve G631-3006B stocks for fast delivery
MOOG Servo valve G761-3033B stocks for fast delivery
Eaton PVH Variable Displacement Piston Pumps - Stocks for Sale
Eaton Solenoid Operated Directional Valve DG4V
Eaton Solenoid Operated Directional Valve DG4V-5-2
Moog Servo valves D633, D634
Moog Servo Valve 072 Series - Stocks for Sale
Servo valves D661-MOOG Valves for Sale
X20AT4222 X20 Input Module - B&R Supplier in China
Products Mode:
AT
Add to Basket
Inquery Now
Prev
Next
Description
X20AT4222 X20 Input Module
MATERIAL NUMBER:
X20AT4222
DESCRIPTION:
4 inputs for resistance temperature measurement
For PT100 and PT1000
Configurable sensor type per channel
Direct resistance measurement
Configurable 2- or 3- wire connections per module
Configurable filter time
The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.
Short description
I/O module
4 inputs for Pt100 or Pt1000 resistance temperature measurement
General information
B&R ID code
0x1BA7
Status indicators
I/O function per channel, operating state, module status
Diagnostics
Module run/error
Yes, using LED status indicator and software
Inputs
Yes, using LED status indicator and software
Power consumption
Bus
0.01 W
Internal I/O
1.1 W
Additional power dissipation caused by actuators (resistive) [W]
-
Certifications
CE
Yes
UKCA
Yes
ATEX
Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X
UL
cULus E115267
Industrial control equipment
HazLoc
cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5
DNV
Temperature:
B
(0 - 55°C)
Humidity:
B
(up to 100%)
Vibration:
B
(4 g)
EMC:
B
(bridge and open deck)
LR
ENV1
KR
Yes
ABS
Yes
EAC
Yes
KC
Yes
Resistance measurement temperature inputs
Input
Resistance measurement with constant current supply for 2- or 3-wire connections
Digital converter resolution
16-bit
Filter time
Configurable between 1 ms and 66.7 ms
Conversion time
1 channel
20 ms with 50 Hz filter
2 - 4 channels
40 ms per channel with 50 Hz filter
Conversion procedure
Sigma-delta
Output format
INT or UINT for resistance measurement
Sensor
Sensor type
Configurable per channel
Pt100
-200 to 850°C
Pt1000
-200 to 850°C
Resistance measurement range
0.1 to 4500 Ω / 0.05 to 2250 Ω
Input filter
First-order low-pass filter / cutoff frequency 500 Hz
Sensor standard
EN 60751
Common-mode range
>0.7 V
Insulation voltage between channel and bus
500 V
eff
Linearization method
Internal
Measurement current
250 µA ±1.25%
Reference
4530 Ω ±0.1%
Permissible input signal
Short-term max. ±30 V
Max. error at 25°C
Gain
0.037%
Offset
0.0015%
Max. gain drift
0.004%/°C
Max. offset drift
0.00015%/°C
Nonlinearity
<0.001%
Crosstalk between channels
<-93 dB
Temperature sensor resolution
Pt100
1 LSB = 0.1°C
Pt1000
1 LSB = 0.1°C
Resistance measurement resolution
G = 1
0.1 Ω
G = 2
0.05 Ω
Common-mode rejection
50 Hz
>80 dB
DC
>95 dB
Standardized range of values for resistance measurement
G = 1
0.1 to 4500 Ω
G = 2
0.05 to 2250 Ω
Temperature sensor normalization
Pt100
-200.0 to 850.0°C
Pt1000
-200.0 to 850.0°C
Temperature measurement monitoring
Range undershoot
0x8001
Range overshoot
0x7FFF
Open circuit
0x7FFF
General fault
0x8000
Open inputs
0x7FFF
Resistance measurement monitoring
Range overshoot
0xFFFF
Open circuit
0xFFFF
General fault
0xFFFF
Open inputs
0xFFFF
Electrical properties
Electrical isolation
Channel isolated from bus
Channel not isolated from channel
Operating conditions
Mounting orientation
Horizontal
Yes
Vertical
Yes
Installation elevation above sea level
0 to 2000 m
No limitation
>2000 m
Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529
IP20
Ambient conditions
Temperature
Operation
Horizontal mounting orientation
-25 to 60°C
Vertical mounting orientation
-25 to 50°C
Derating
-
Storage
-40 to 85°C
Transport
-40 to 85°C
Relative humidity
Operation
5 to 95%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical properties
Note
Order 1x terminal block X20TB12 separately.
Order 1x bus module X20BM11 separately.
Pitch
12.5
+0.2
mm